Fire door refers to the door that can meet the requirements of fire stability, integrity and heat insulation, but in real life, many fire doors do not have a greater function of fire prevention. So how should the function of the fire door to play to the greater? The following by the fire door manufacturers to tell you.

1, in the closed staircase, smoke staircase, fire elevator and its front room and other personnel frequent access to the fire door, should be based on the use of the building function, the nature of the fire door at ordinary times to determine the opening and closing state. For example, normally closed fire doors can be set for residential buildings, and normally open fire doors should be set for public buildings and factories. Specifically, normally open fire doors should be used for personnel passing through during normal use, and normally closed fire doors should be used for personnel passing through during normal use.

Article 7.5.2 of the "Construction Regulations" stipulates that normally open fire doors should be able to close on their own in case of fire and should have the function of signal feedback. In fact, the normally closed fire door should also have the same signal feedback function as the normally open fire door, and the feedback signal of the normally closed fire door should also be able to reflect whether the closing sequence of the double doors is normal, so that the personnel on duty in the fire control room can timely grasp the opening and closing conditions of the fire door, timely handle the fire door with poor closing conditions, and repair the fire door with similar door closer damage and hinge loosening, ensure the fire prevention and smoke prevention efficiency of the normally closed fire door.

3. There is no clear performance requirement for the sequencer of the double fire door in the industry standard. It is recommended to increase the specific and quantitative standards such as the installation site, action mode, reaction time, and number of actions of the sequencer in the industry standard, so as to make it a practical and specific provision.

4. According to the specific requirements of no fire door closer product quality standard, no installation method and firmness in the industry standard, it is suggested to increase the comparison table between the door closer tension and the door quality in the industry standard to standardize the use specification of the door closer; Increase the installation firmness standard of the door closer, specify the specific action times of the door closer, so as to ensure that the fire door remains in a good closed state for a long time; Increase the opening angle requirements of the door closer, break through the 90 ° stereotypes determined by the manufacturer itself, so that the fire door can meet the needs of use and market needs.

5, the selection of fireproof hinge, should be used to separate, removable hinge, so that when installing the fire door, you can be fixed firmly, and then directly insert the door leaf into the door frame.

6. When fixing hinges and door closers, the current fixing method with wood screws should be changed. Holes for fixing hinges should be reserved on the door frame and door leaf, and then relevant screws and nuts should be matched. In this way, standardized operations can be carried out according to the reserved holes when the installation site is reached. Screws and nuts on the door leaf should also be equipped with corresponding heat insulation decorations.

7, to determine the use of double, multi-fan fire door, should be reserved in the construction process of signal feedback line, fire door installation unit should contact with the construction unit, building fire engineering construction unit as soon as possible, reserved lines and control modules, in order to facilitate the installation and commissioning of fire doors.

Related News


Jiangsu Yaya Door Industry Group Co., Ltd. was awarded "Excellent Supplier" in 2022"

In 2022, the decoration company of the second construction co., ltd. of the eighth bureau of China construction awarded Jiangsu yaya door industry group co., ltd. as an "excellent supplier"


Buy security door should pay attention to the following four points

Distinguish the difference between anti-theft door and metal door, do not trust the propaganda of sales staff, when ordering, the operator should indicate the anti-theft door in the commodity name column, in order to prevent illegal operators from using "steel door", "protective door", "anti-pry door", "armored door" and so on as anti-theft door;


How to judge the quality of door and window enclosure components in the home

Doors and windows are the two enclosure components in the house. The main functions are for traffic access, separation and connection of building space, ventilation and lighting, etc. The general requirements for checking doors and windows are that the installation is flat and firm, there is no warping deformation, the opening is convenient and flexible, the closing is tight, the function is reasonable, the maintenance is convenient, the spare parts are fully assembled and the position is accurate.


Fire door manufacturers to introduce you to the classification of fire doors

According to the different materials, fire doors can also be divided into steel, wood fire doors and glass fire doors. Wooden fire door refers to the use of wood or wood products for the door frame, door panel, skeleton, filled with non-combustible materials inside the door leaf, and equipped with hardware parts to meet the fire stability, integrity and heat insulation requirements of the door. Steel fire door refers to the use of cold-rolled thin steel plate for the door frame, door panel, skeleton, in the door leaf filled with non-combustible materials, and with hardware parts composed of can meet the fire stability, integrity and heat insulation requirements of the door. Glass fire door refers to the steel fire door with fireproof glass as the door panel.


Technical Requirements of Wooden Fire Door Manufacturers

According to the requirements of building fire protection regulations such as "building design fire protection code", fire doors are used for the opening of firewall, staircase entrance and exit, evacuation walkway, pipeline well opening and other parts, and play the role of fire separation. According to the material, the fire door is usually divided into two categories: steel fire door and wooden fire door. Now the fire door manufacturer introduces the wooden fire door.


Fire door manufacturers introduce the development of fire door prices

With the continuous development and improvement of the market economy, the price of fire doors has also changed. At the same time, due to the increase of labor cost and raw material cost, the price of fire door also fluctuates. The following by the fire door manufacturers to introduce the development of fire door prices.